Highest 90 PSI flow in this 12-model group at 6.5 CFM, with wheels and a folding handle. The manual still limits pumping time to half of each hour.
Published specifications
- Delivered airflow
- 6.9 CFM at 40 PSI; 6.5 CFM at 90 PSI
- Tank
- 5.2 US gal
- Maximum pressure
- 140 PSI
- Duty share
- 50% — see definition
- Duty definition
- No more than 50% compressor pumping time within each hour (owner manual).
- Power
- 120 V · 60 Hz
- Published current
- 13.8 A — Owner manual: amperage at maximum pressure, not startup surge.
- Published sound
- Not confirmed
- Sound conditions
- Measurement distance and method not specified in consulted manufacturer sources.
- Weight
- 88 lb
- Machine dimensions
- Not confirmed
- Pump type
- oil-lubricated
Your tool. Your working schedule.
Example schedule: 10 trigger seconds each minute. Change it to reflect your job.
Pump duty needs review
Average flow is within the published delivery rating, but burst demand, duty data or operating limits still need checking. This is not a compatibility approval.
Manufacturer application limits
For referenceNo category restriction is recorded in this dataset. Check the model manual for your application.
Working pressure
Within this criterionThe tool’s 90 PSI requirement is within the compressor’s 140 PSI pressure ceiling. This does not establish pressure delivered through the regulator, hose and fittings.
Air demand versus published delivery
Within this criterionThis schedule averages 3.67 CFM against 6.5 CFM at 90 PSI. This checks average air balance, not pressure throughout each trigger pull.
Airflow during a trigger pull
Check the conditionsWhile the trigger is held, 22 CFM exceeds the 6.5 CFM delivery rating. Stored air may help a short burst, but pressure-switch behavior, burst length and losses have not been simulated.
Pump duty
Check the conditionsA simplified air balance implies 56.41% pump-on time; the recorded duty share is 50%. The estimated requirement exceeds that share. No more than 50% compressor pumping time within each hour (owner manual). This is not a measured cycle or a continuous-use approval.
Session duration
Check the conditions30 minutes is recorded for your planned session. Model-specific duration limits, cooling breaks and actual cycling are not automatically validated. This field does not change the airflow calculation.
Hose and connections
Check the conditionsThe tool specifies a minimum 0.38-inch hose inside diameter; its recorded air inlet is 0.25 inch. Confirm thread type, coupler profile, hose length and available flow separately; matching nominal sizes alone is not a connection check.
Calculation details
56% estimated pump-on share from average demand ÷ rated delivery. This is an air-balance estimate, not an observed duty cycle or permission to run continuously.
3.9 seconds of theoretical stored-air drawdown over 120 → 90 PSI, with the pump off and a continuous trigger pull. This is not actual operating time, recharge time, or storage life.
Specification screening only. Actual pressure at the tool, hose losses, pump cycling and installation conditions are not established by an average-flow calculation.
Reading the result for this model
The MAC5200 publishes 6.5 CFM at 90 PSI. The matcher compares a repeating trigger schedule with a delivery point at the tool’s confirmed pressure. A passing average-flow check does not establish outlet pressure throughout a burst.
Tank volume affects the amount of air stored between two pressures; it does not change the published pump delivery. Review the optional buffer estimate separately from duty and session limits.
Manufacturer sources
Checked 25 October 2026. Specifications can change; verify the exact model and market before purchase.
Look up this model at the retailer.
This opens Amazon search results for Makita MAC5200, not a verified product listing. Check the exact model, market version and accessories. No live price or stock is shown.