ToolSpecLabCHECK FIRST. CHOOSE BETTER.INDEPENDENT TOOL CHECKS
California Air Tools

2010A
air-supply check.

Two-gallon aluminum tank and the same 2.2 CFM at 90 PSI as the larger 8010. Choose by carrying weight, burst reserve and floor space rather than assuming a larger motor.

2 GAL

Published specifications

Delivered airflow
3.1 CFM at 40 PSI; 2.2 CFM at 90 PSI
Tank
2 US gal
Maximum pressure
120 PSI
Duty share
70% — see definition
Duty definition
70% running / 30% stopped across a standard workday; additional continuous-use limits apply.
Power
110 V · 60 Hz
Published current
8.5 A — Manufacturer low amp draw; running/startup basis not distinguished.
Published sound
60 dB
Sound conditions
Measurement distance and method not stated in consulted manufacturer page.
Weight
Not confirmed
Machine dimensions
18.7 × 14.2 × 14.75 in (L,W,H)
Pump type
oil-free
CHECK THE PAIRING

Your tool. Your working schedule.

Example schedule: 10 trigger seconds each minute. Change it to reflect your job.

Your setup

Session length is recorded for checking the manual. It does not predict a safe operating time.

Add confirmed missing specifications

Use figures from your exact model’s label or manual. These entries remain user supplied and are not added to our catalog.

California Air Tools 2010A

Demand exceeds a published limit

The entered workload exceeds a documented pressure or average-flow limit. Review the failed checks below before selecting this pairing.

Your average air demand3.67 CFM10 seconds of trigger time per minute · 1 tool · 30-minute session
Published compressor delivery2.20 CFMAt 90.0 PSI
  1. Manufacturer application limits

    For reference

    No category restriction is recorded in this dataset. Check the model manual for your application.

  2. Working pressure

    Within this criterion

    The tool’s 90 PSI requirement is within the compressor’s 120 PSI pressure ceiling. This does not establish pressure delivered through the regulator, hose and fittings.

  3. Air demand versus published delivery

    Does not meet this criterion

    This schedule requires 3.67 CFM on average, above 2.2 CFM published at 90 PSI. A larger tank alone does not close the ongoing air-supply deficit.

  4. Airflow during a trigger pull

    Check the conditions

    While the trigger is held, 22 CFM exceeds the 2.2 CFM delivery rating. Stored air may help a short burst, but pressure-switch behavior, burst length and losses have not been simulated.

  5. Pump duty

    Check the conditions

    A simplified air balance implies 166.67% pump-on time; the recorded duty share is 70%. The estimated requirement exceeds that share. 70% running / 30% stopped across a standard workday; additional continuous-use limits apply. This is not a measured cycle or a continuous-use approval.

  6. Session duration

    Check the conditions

    30 minutes is recorded for your planned session. Model-specific duration limits, cooling breaks and actual cycling are not automatically validated. This field does not change the airflow calculation.

  7. Hose and connections

    Check the conditions

    The tool specifies a minimum 0.38-inch hose inside diameter; its recorded air inlet is 0.25 inch. Confirm thread type, coupler profile, hose length and available flow separately; matching nominal sizes alone is not a connection check.

Calculation details

167% estimated pump-on share from average demand ÷ rated delivery. This is an air-balance estimate, not an observed duty cycle or permission to run continuously.

1.5 seconds of theoretical stored-air drawdown over 120 → 90 PSI, with the pump off and a continuous trigger pull. This is not actual operating time, recharge time, or storage life.

Specification screening only. Actual pressure at the tool, hose losses, pump cycling and installation conditions are not established by an average-flow calculation.

Reading the result for this model

The 2010A publishes 2.2 CFM at 90 PSI. The matcher compares a repeating trigger schedule with a delivery point at the tool’s confirmed pressure. A passing average-flow check does not establish outlet pressure throughout a burst.

Tank volume affects the amount of air stored between two pressures; it does not change the published pump delivery. Review the optional buffer estimate separately from duty and session limits.

Manufacturer sources

Checked 25 October 2026. Specifications can change; verify the exact model and market before purchase.

Look up this model at the retailer.

This opens Amazon search results for California Air Tools 2010A, not a verified product listing. Check the exact model, market version and accessories. No live price or stock is shown.

As an Amazon Associate I earn from qualifying purchases.

Search this model on Amazon ↗