Airflow difference
At 90 PSI, the published delivery changes from 0.7 CFM on the MAC100Q to 2 CFM on the MAC210Q. Compare those ratings with your tool’s at-load demand and usage pattern.
Compare capacity and portability within the manual’s nailer/stapler application limits.
| What to compare | MAC100Q | MAC210Q |
|---|---|---|
| Air delivery at 90 PSI | 0.7 CFM | 2 CFM |
| Tank volume | 1 US gal | 2 US gal |
| Duty share | 50% — see manual | 50% — see manual |
| Published noise* | 58 dB | 60 dB |
| Pump type | oil-free | oil-free |
| Weight | 27.6 lb | 45.2 lb |
| Supply voltage | 120 V | 120 V |
*Noise readings are manufacturer figures; measurement methods and distances are not consistently available.
At 90 PSI, the published delivery changes from 0.7 CFM on the MAC100Q to 2 CFM on the MAC210Q. Compare those ratings with your tool’s at-load demand and usage pattern.
The tanks are 1 and 2 US gallons. Over the same pressure interval, stored free-air volume scales with tank volume. Recovery time also depends on delivery across that interval and is not inferred here.
MAC100Q: No more than 50% compressor pumping time within each hour (owner manual).
MAC210Q: No more than 50% compressor pumping time within each hour (owner manual).
One or both models have captured manufacturer application restrictions. The matcher reports these before an airflow result can be treated as a reason to select the model.
Example schedule: 10 trigger seconds each minute. Change it to reflect your job.
The manufacturer application limit is a deciding constraint for this pairing. Airflow arithmetic does not override it.
The captured manufacturer guidance limits this compressor to nailer / stapler applications. This tool is categorized as impact-wrench. A favorable airflow calculation does not override that restriction.
The tool’s 90 PSI requirement is within the compressor’s 135 PSI pressure ceiling. This does not establish pressure delivered through the regulator, hose and fittings.
This schedule requires 3.67 CFM on average, above 0.7 CFM published at 90 PSI. A larger tank alone does not close the ongoing air-supply deficit.
While the trigger is held, 22 CFM exceeds the 0.7 CFM delivery rating. Stored air may help a short burst, but pressure-switch behavior, burst length and losses have not been simulated.
A simplified air balance implies 523.81% pump-on time; the recorded duty share is 50%. The estimated requirement exceeds that share. No more than 50% compressor pumping time within each hour (owner manual). This is not a measured cycle or a continuous-use approval.
30 minutes is recorded for your planned session. Model-specific duration limits, cooling breaks and actual cycling are not automatically validated. This field does not change the airflow calculation.
The tool specifies a minimum 0.38-inch hose inside diameter; its recorded air inlet is 0.25 inch. Confirm thread type, coupler profile, hose length and available flow separately; matching nominal sizes alone is not a connection check.
524% estimated pump-on share from average demand ÷ rated delivery. This is an air-balance estimate, not an observed duty cycle or permission to run continuously.
0.7 seconds of theoretical stored-air drawdown over 120 → 90 PSI, with the pump off and a continuous trigger pull. This is not actual operating time, recharge time, or storage life.
Specification screening only. Actual pressure at the tool, hose losses, pump cycling and installation conditions are not established by an average-flow calculation.
The manufacturer application limit is a deciding constraint for this pairing. Airflow arithmetic does not override it.
The captured manufacturer guidance limits this compressor to nailer / stapler applications. This tool is categorized as impact-wrench. A favorable airflow calculation does not override that restriction.
The tool’s 90 PSI requirement is within the compressor’s 135 PSI pressure ceiling. This does not establish pressure delivered through the regulator, hose and fittings.
This schedule requires 3.67 CFM on average, above 2 CFM published at 90 PSI. A larger tank alone does not close the ongoing air-supply deficit.
While the trigger is held, 22 CFM exceeds the 2 CFM delivery rating. Stored air may help a short burst, but pressure-switch behavior, burst length and losses have not been simulated.
A simplified air balance implies 183.33% pump-on time; the recorded duty share is 50%. The estimated requirement exceeds that share. No more than 50% compressor pumping time within each hour (owner manual). This is not a measured cycle or a continuous-use approval.
30 minutes is recorded for your planned session. Model-specific duration limits, cooling breaks and actual cycling are not automatically validated. This field does not change the airflow calculation.
The tool specifies a minimum 0.38-inch hose inside diameter; its recorded air inlet is 0.25 inch. Confirm thread type, coupler profile, hose length and available flow separately; matching nominal sizes alone is not a connection check.
183% estimated pump-on share from average demand ÷ rated delivery. This is an air-balance estimate, not an observed duty cycle or permission to run continuously.
1.5 seconds of theoretical stored-air drawdown over 120 → 90 PSI, with the pump off and a continuous trigger pull. This is not actual operating time, recharge time, or storage life.
Specification screening only. Actual pressure at the tool, hose losses, pump cycling and installation conditions are not established by an average-flow calculation.
Checked 25 October 2026. Specifications can change; verify the exact model and market before purchase.